Blinken - Impulsgenerator mit variablem Tastgrad
Blinken - Impulsgenerator mit variablem Tastgrad
Import
Die folgende Definition kann als Testraum in die eigene FHEM-Installation ohne Seiteneffekte importiert werden, indem man auf das Pluszeichen oben links im Webinterface klickt. Falls dieses unsichtbar sein sollte, kann es z.B über den Style f18 sichtbar gemacht werden.
defmod Pulse MSwitch # MSwitch_Self pulsedevice
attr Pulse MSwitch_Debug 0
attr Pulse MSwitch_Delete_Delays 1
attr Pulse MSwitch_Eventhistory 0
attr Pulse MSwitch_Expert 1
attr Pulse MSwitch_Extensions 1
attr Pulse MSwitch_Help 1
attr Pulse MSwitch_Ignore_Types "TYPE=MSwitch"
attr Pulse MSwitch_Include_Devicecmds 1
attr Pulse MSwitch_Include_MSwitchcmds 0
attr Pulse MSwitch_Include_Webcmds 0
attr Pulse MSwitch_Inforoom MSwitch
attr Pulse MSwitch_Lock_Quickedit 1
attr Pulse MSwitch_Mode Full
attr Pulse MSwitch_Safemode 1
attr Pulse readingList onpulse offpulse
attr Pulse room 07_Pulse
attr Pulse setList onpulse:00:00:01,00:00:02,00:00:03,00:00:04,00:00:05 offpulse:00:00:01,00:00:02,00:00:03,00:00:04,00:00:05
attr Pulse webCmd on:off:onpulse:offpulse
attr Pulse webCmdLabel ::ontime:offtime
defmod pulsedevice MSwitch # no_device
attr pulsedevice MSwitch_Debug 0
attr pulsedevice MSwitch_Eventhistory 0
attr pulsedevice MSwitch_Help 0
attr pulsedevice MSwitch_Ignore_Types notify allowed at watchdog doif fhem2fhem telnet FileLog readingsGroup FHEMWEB autocreate eventtypes readingsproxy svg cul
attr pulsedevice MSwitch_Inforoom MSwitch
attr pulsedevice MSwitch_Mode Dummy
attr pulsedevice room 07_Pulse
attr pulsedevice setList on off
setstate Pulse off
setstate Pulse 2019-11-03 14:17:18 .Device_Affected MSwitch_Self-AbsCmd1,MSwitch_Self-AbsCmd2,pulsedevice-AbsCmd1,pulsedevice-AbsCmd2
setstate Pulse 2019-11-03 14:21:52 .Device_Affected_Details MSwitch_Self-AbsCmd1#[NF]exec_cmd_1#[NF]no_action#[NF]ID#[sp]1#[NF]#[NF]delay1#[NF]delay1#[NF][Pulse#[dp]onpulse]#[NF]00#[dp]00#[dp]00#[NF]#[NF]#[NF]0#[NF]0#[NF]1#[NF]0#[NF]#[NF]0#[NF]0#[NF]3#[ND]MSwitch_Self-AbsCmd2#[NF]exec_cmd_1#[NF]no_action#[NF]#[NF]#[NF]delay1#[NF]delay1#[NF][Pulse#[dp]offpulse]#[NF]00#[dp]00#[dp]00#[NF]#[NF]#[NF]0#[NF]0#[NF]1#[NF]1#[NF]#[NF]0#[NF]0#[NF]4#[ND]pulsedevice-AbsCmd1#[NF]on#[NF]off#[NF]#[NF]#[NF]delay1#[NF]delay1#[NF]00#[dp]00#[dp]00#[NF]00#[dp]00#[dp]00#[NF]#[NF]#[NF]0#[NF]0#[NF]1#[NF]0#[NF]#[NF]0#[NF]0#[NF]1#[ND]pulsedevice-AbsCmd2#[NF]off#[NF]no_action#[NF]#[NF]#[NF]delay2#[NF]delay1#[NF][Pulse#[dp]onpulse]#[NF]00#[dp]00#[dp]00#[NF]#[NF]#[NF]0#[NF]0#[NF]1#[NF]0#[NF]#[NF]0#[NF]0#[NF]2
setstate Pulse 2019-11-03 12:31:25 .Device_Events no_trigger
setstate Pulse 2019-11-03 12:31:25 .First_init done
setstate Pulse 2019-11-03 12:31:25 .Trigger_cmd_off no_trigger
setstate Pulse 2019-11-03 12:31:25 .Trigger_cmd_on no_trigger
setstate Pulse 2019-11-03 12:31:25 .Trigger_off no_trigger
setstate Pulse 2019-11-03 12:31:25 .Trigger_on no_trigger
setstate Pulse 2019-11-03 12:31:25 .V_Check V2.00
setstate Pulse 2019-11-03 14:18:43 .sortby show
setstate Pulse 2019-11-03 12:31:25 Trigger_log off
setstate Pulse 2019-11-03 14:21:24 last_activation_by manual
setstate Pulse 2019-11-03 14:21:23 last_cmd 1
setstate Pulse 2019-11-03 14:21:23 last_exec_cmd set Pulse exec_cmd_1
setstate Pulse 2019-11-03 14:21:05 offpulse 00:00:05
setstate Pulse 2019-11-03 14:19:18 onpulse 00:00:02
setstate Pulse 2019-11-03 14:21:24 state off
setstate pulsedevice on
setstate pulsedevice 2019-11-03 12:32:30 .Device_Affected no_device
setstate pulsedevice 2019-11-03 12:32:30 .Device_Events no_trigger
setstate pulsedevice 2019-11-03 12:32:30 .First_init done
setstate pulsedevice 2019-11-03 12:32:30 .Trigger_cmd_off no_trigger
setstate pulsedevice 2019-11-03 12:32:30 .Trigger_cmd_on no_trigger
setstate pulsedevice 2019-11-03 12:32:30 .Trigger_off no_trigger
setstate pulsedevice 2019-11-03 12:32:30 .Trigger_on no_trigger
setstate pulsedevice 2019-11-03 12:32:30 .V_Check V2.00
setstate pulsedevice 2019-11-03 12:32:30 Trigger_log off
Inbetriebnahme
Der Testraum 07_Puls enthält zwei konfigurierte MSwitch-Geräte, die die beabsichtigte Funktion zusammen bewirken. Pulse enthält die Logik, Pulsedevice dient der Statusausgabe des Generators. Als einziges muss in Pulse eine Auslösezeit in die obere Zeile (switch MSwitch on + execute 'cmd1' at :) im Format hh:mm:ss geschrieben werden, um die Impulsfolge zu starten.
Nach der Auslösung liefert das Pulsdevice eine endlose konfigurierbare Folge von Rechtecksignalen. Pulsdevice im Testraum in Aktion:
Funktionsbeschreibung
1. Auslösung des MSwitch-Gerätes 'Pulse' beim Erreichen der angegebenen Triggertime,
2. Aktivieren des 1. Befehlszweiges 'cmd1' des MSwitch-Gerätes 'Pulse',
3. Auswahl betroffener Geräte: 'MSwitch_Self -> pulse' und 'pulsedevice', Erzeugung je eines 'device action'-Rahmens
4. unverzögertes Setzen des Status von 'pulsedevice' auf 'on', positive Flanke des Rechtecksignals
5. um die Länge von 'onpulse' verzögertes Rücksetzen des Status von 'pulsdevice', negative Flanke des Rechtecksignals
6. um die Länge von 'offpulse' verzögertes Ausführen von 'Set exec_cmd_1', Verweis auf ID1, Pausenzeit vor nächstem Impuls
Anpassung an eigene Anforderungen
Um eigene Geräte für die Ausgabe benutzen zu können, muss:
Attribut Switch_Ignore_Types = TYPE=MSwitch
auf
Attribut Switch_Ignore_Types = notify allowed at watchdog doif fhem2fhem telnet FileLog readingsGroup FHEMWEB autocreate eventtypes readingsproxy svg cul
geändert werden.
Um den Verlust von Konfigurationsdaten zu vermeiden, lässt man das quickedit verriegelt und fügt eigene Zielgeräte per 'edit list' hinzu.
Die Bestätigung mit 'modify Devices' erzeugt pro neuem Gerät einen 'device action'-Rahmen, in den die Konfiguration von 'pulsedevice' übernommen werden kann. 'Modify action' übernimmt.
Der zweite notwendige Action-Rahmen für das eigene Device wird per 'add action ..' erzeugt.
Das Attribut 'setlist' erlaubt die leichte Anpassung der auswählbaren Impuls- bzw. Pausenzeiten. Hier können auch Dezimalbrüche wie 0,5 angegeben werden.