SolarEdge Wechselrichter: Unterschied zwischen den Versionen
(→Am Wechselrichter: Zeitweise Aktivität) |
(→List von Device Solaredge in FHEM: Userreadings eingeführt) |
||
Zeile 48: | Zeile 48: | ||
DEST 192.168.178.36:502 | DEST 192.168.178.36:502 | ||
DeviceName 192.168.178.36:502 | DeviceName 192.168.178.36:502 | ||
FD | FD 91 | ||
INTERVAL | INTERVAL 600 | ||
IODev KeSolarEdge | IODev KeSolarEdge | ||
LASTOPEN | LASTOPEN 1523044866.65275 | ||
MODBUSID 1 | MODBUSID 1 | ||
ModuleVersion 3.7. | ModuleVersion 3.7.3 - 22.12.2017 | ||
NAME KeSolarEdge | NAME KeSolarEdge | ||
NOTIFYDEV global | NOTIFYDEV global | ||
NR | NR 354 | ||
NTFY_ORDER 50-KeSolarEdge | NTFY_ORDER 50-KeSolarEdge | ||
PARTIAL | PARTIAL | ||
PROTOCOL TCP | PROTOCOL TCP | ||
REQUESTHEX | REQUESTHEX 00270000000601039c940001 | ||
STATE | STATE 0 W; 1718 kWh | ||
TRIGGERTIME | TRIGGERTIME 1523048587.13296 | ||
TRIGGERTIME_FMT | TRIGGERTIME_FMT 2018-04-06 23:03:07 | ||
TYPE ModbusAttr | TYPE ModbusAttr | ||
devioLoglevel | devioLoglevel 4 | ||
nextOpenDelay 60 | nextOpenDelay 60 | ||
QUEUE: | |||
READINGS: | |||
2018-04-06 22:53:07 AC-Energy 1717.665 | |||
2018-04-06 22:53:07 AC-Energy-Scale 0 | |||
2018-04-06 22:53:07 AC-Energy-Val 1717665 | |||
2018-04-06 22:58:10 AC-Power 0 | |||
2018-04-06 22:58:10 AC-Power-Scale 0 | |||
2018-04-06 22:58:10 AC-Power-Val 0 | |||
2018-04-06 22:53:07 DC-Current 0 | |||
2018-04-06 22:53:07 DC-Current-Scale -32768 | |||
2018-04-06 22:53:07 DC-Current-Val 65535 | |||
2018-04-06 22:53:07 DC-Power 0 | |||
2018-04-06 22:53:07 DC-Power-Scale 0 | |||
2018-04-06 22:53:07 DC-Power-Val 0 | |||
2018-04-06 22:53:07 DC-Voltage 0 | |||
2018-04-06 22:53:07 DC-Voltage-Scale -1 | |||
2018-04-06 22:53:07 DC-Voltage-Val 0 | |||
2018-04-06 22:53:07 HeatSinkTemp 0 | |||
2018-04-06 22:53:07 Status 2 | |||
2018-04-06 22:53:07 Zustand Nachtmodus | |||
2018-04-06 22:01:06 state opened | |||
defptr: | |||
1: | |||
gotReadings: | |||
AC-Power-Scale 0 | |||
helper: | |||
buffer | |||
lid 1 | |||
lrecv 1523048290.49688 | |||
lsend 1523048290.48976 | |||
lastRead: | |||
h40083 1523048290.48193 | |||
h40084 1523048290.50143 | |||
h40093 1523047987.08669 | |||
h40095 1523047987.09043 | |||
h40096 1523047987.09428 | |||
h40097 1523047987.09784 | |||
h40098 1523047987.10153 | |||
h40099 1523047987.10505 | |||
h40100 1523047987.10867 | |||
h40101 1523047987.11226 | |||
h40103 1523047987.1158 | |||
h40107 1523047987.11994 | |||
Attributes: | Attributes: | ||
dev-h-combine 200 | |||
dev-h-defPoll 1 | dev-h-defPoll 1 | ||
dev-h-defShowGet 1 | dev-h-defShowGet 1 | ||
enableControlSet 1 | enableControlSet 1 | ||
event-on-change-reading .* | |||
event-on-update-reading AC-Energy,AC-Energy-Scale,AC-Power-Scale,DC-Voltage-Scale,DC-Current-Scale,DC-Power-Scale,Status | |||
maxTimeoutsToReconnect 3 | maxTimeoutsToReconnect 3 | ||
obj-h40083-reading AC-Power-Val | |||
obj-h40083-reading AC-Power | |||
obj-h40084-reading AC-Power-Scale | obj-h40084-reading AC-Power-Scale | ||
obj-h40084-unpack s> | obj-h40084-unpack s> | ||
obj-h40093-len 2 | obj-h40093-len 2 | ||
obj-h40093-reading AC-Energy | obj-h40093-reading AC-Energy-Val | ||
obj-h40093-unpack l> | obj-h40093-unpack l> | ||
obj-h40095-reading AC-Energy-Scale | obj-h40095-reading AC-Energy-Scale | ||
obj-h40096-reading DC-Current | obj-h40096-reading DC-Current-Val | ||
obj-h40097-reading DC-Current-Scale | obj-h40097-reading DC-Current-Scale | ||
obj-h40097-unpack s> | obj-h40097-unpack s> | ||
obj-h40098-reading DC-Voltage | obj-h40098-reading DC-Voltage-Val | ||
obj-h40099-reading DC-Voltage-Scale | obj-h40099-reading DC-Voltage-Scale | ||
obj-h40099-unpack s> | obj-h40099-unpack s> | ||
obj-h40100-reading DC-Power | obj-h40100-reading DC-Power-Val | ||
obj-h40101-reading DC-Power-Scale | obj-h40101-reading DC-Power-Scale | ||
obj-h40101-unpack s> | obj-h40101-unpack s> | ||
Zeile 95: | Zeile 137: | ||
obj-h40103-unpack s> | obj-h40103-unpack s> | ||
obj-h40107-reading Status | obj-h40107-reading Status | ||
room Solar,SolarPV,SolarReport | |||
silentReconnect 1 | |||
sortUpdate 1 | |||
stateFormat {sprintf("%.0f W; %.0f kWh",ReadingsVal("KeSolarEdge","AC-Power",0),ReadingsVal("KeSolarEdge","AC-Energy",0))} | |||
userReadings AC-Energy:(AC-Energy-Scale.*) { | |||
my $scale = ReadingsVal ("KeSolarEdge","AC-Energy-Scale",0); | |||
return (ReadingsVal ("KeSolarEdge","AC-Energy-Val",0) * ( 10 ** $scale) / 1000);;}, | |||
AC-Power:(AC-Power-Scale.*) { | |||
my $scale = ReadingsVal ("KeSolarEdge","AC-Power-Scale",0); | |||
return (ReadingsVal ("KeSolarEdge","AC-Power-Val",0) * ( 10 ** $scale));;}, | |||
DC-Power:(DC-Power-Scale.*) { | |||
my $scale = ReadingsVal ("KeSolarEdge","DC-Power-Scale",0); | |||
return (ReadingsVal ("KeSolarEdge","DC-Power-Val",0) * ( 10 ** $scale));;}, | |||
DC-Current:(DC-Current-Scale.*) { | |||
my $scale = ReadingsVal ("KeSolarEdge","DC-Current-Scale",0); | |||
return (ReadingsVal ("KeSolarEdge","DC-Current-Val",0) * ( 10 ** $scale));;}, | |||
DC-Voltage:(DC-Voltage-Scale.*) { | |||
my $scale = ReadingsVal ("KeSolarEdge","DC-Voltage-Scale",0); | |||
return (ReadingsVal ("KeSolarEdge","DC-Voltage-Val",0) * ( 10 ** $scale));;}, | |||
Zustand:(Status.*) { | |||
my $Zus = ReadingsVal("KeSolarEdge","Status",0); | |||
my $rueck = ReadingsVal("KeSolarEdge","Zustand",0); | |||
if (($Zus == 2) and (InternalVal("KeSolarEdge","INTERVAL","") != 600)) { | |||
fhem("set KeSolarEdge interval 600"); | |||
$rueck = "Nachtmodus"; | |||
} | |||
elsif (InternalVal("KeSolarEdge","INTERVAL","") != 60) { | |||
fhem("set KeSolarEdge interval 60"); | |||
$rueck = "Tagmodus"; | |||
} | |||
return ($rueck);; | |||
} | |||
webCmdLabel {sprintf("AC-Energy %.3f",ReadingsVal("Solaredge","AC-Energy",0));;} | |||
</pre> | </pre> | ||
Version vom 6. April 2018, 22:05 Uhr
SolarEdge Wechselrichter | |
---|---|
Allgemein | |
Protokoll | Modubus TCP |
Typ | Wechselrichter |
Kategorie | Energieverbrauchsmessung |
Technische Details | |
Kommunikation | Ethernet TCP |
Kanäle | 1 (bidiektional) |
Betriebsspannung | 750V DC; 230V 3xAC |
Leistungsaufnahme | Eigenverbrauch 2% (geschätzt) |
Versorgung | 230V~ 3xAC |
Abmessungen | 317x512x214 (mm) |
Sonstiges | |
Modulname | ModbusAttr |
Hersteller | Solaredge |
SE10k von Solaredge in FHEM einbinden
Dieser Artikel beschreibt die Einbindung eines Solaredgewechselrichters SE10k in ein FHEM System über eine Ethernetverbindung mit Hilfe des Moduls ModbusAttr.
Vorbedingungen
FHEM läuft und hat genügend Platz für Modifikationen und Logfiles (ca. 100 MByte / Jahr).
Am Wechselrichter
Im zugehörigen Menu ist bereits der Port 503 eingestellt. Trotzdem muss dieser noch einmal aktiviert werden, da sonst Modbus TCP nicht aktiv wird. Hilfe da zu bietet die Installationsanleitung [1]. Es ist möglich, dass es auch nur 10 Minuten aktiv bleibt wenn er nicht angesprochen wird.
ModbusAttr Device in FHEM
in FHEM wird ein ModbusAttr angelegt
define SolarEdge ModbusAttr 1 30 192.168.178.36 TCP
danach alle Attribute aus dem unten stehenden list nach dem Verfahren:
attr SolarEdge dev-h-defPoll 1
Mehr Daten sind im Sunspec Protokoll [2] zu finden
List von Device Solaredge in FHEM
Internals: BUSY 0 DEF 1 30 192.168.178.36 TCP DEST 192.168.178.36:502 DeviceName 192.168.178.36:502 FD 91 INTERVAL 600 IODev KeSolarEdge LASTOPEN 1523044866.65275 MODBUSID 1 ModuleVersion 3.7.3 - 22.12.2017 NAME KeSolarEdge NOTIFYDEV global NR 354 NTFY_ORDER 50-KeSolarEdge PARTIAL PROTOCOL TCP REQUESTHEX 00270000000601039c940001 STATE 0 W; 1718 kWh TRIGGERTIME 1523048587.13296 TRIGGERTIME_FMT 2018-04-06 23:03:07 TYPE ModbusAttr devioLoglevel 4 nextOpenDelay 60 QUEUE: READINGS: 2018-04-06 22:53:07 AC-Energy 1717.665 2018-04-06 22:53:07 AC-Energy-Scale 0 2018-04-06 22:53:07 AC-Energy-Val 1717665 2018-04-06 22:58:10 AC-Power 0 2018-04-06 22:58:10 AC-Power-Scale 0 2018-04-06 22:58:10 AC-Power-Val 0 2018-04-06 22:53:07 DC-Current 0 2018-04-06 22:53:07 DC-Current-Scale -32768 2018-04-06 22:53:07 DC-Current-Val 65535 2018-04-06 22:53:07 DC-Power 0 2018-04-06 22:53:07 DC-Power-Scale 0 2018-04-06 22:53:07 DC-Power-Val 0 2018-04-06 22:53:07 DC-Voltage 0 2018-04-06 22:53:07 DC-Voltage-Scale -1 2018-04-06 22:53:07 DC-Voltage-Val 0 2018-04-06 22:53:07 HeatSinkTemp 0 2018-04-06 22:53:07 Status 2 2018-04-06 22:53:07 Zustand Nachtmodus 2018-04-06 22:01:06 state opened defptr: 1: gotReadings: AC-Power-Scale 0 helper: buffer lid 1 lrecv 1523048290.49688 lsend 1523048290.48976 lastRead: h40083 1523048290.48193 h40084 1523048290.50143 h40093 1523047987.08669 h40095 1523047987.09043 h40096 1523047987.09428 h40097 1523047987.09784 h40098 1523047987.10153 h40099 1523047987.10505 h40100 1523047987.10867 h40101 1523047987.11226 h40103 1523047987.1158 h40107 1523047987.11994 Attributes: dev-h-combine 200 dev-h-defPoll 1 dev-h-defShowGet 1 enableControlSet 1 event-on-change-reading .* event-on-update-reading AC-Energy,AC-Energy-Scale,AC-Power-Scale,DC-Voltage-Scale,DC-Current-Scale,DC-Power-Scale,Status maxTimeoutsToReconnect 3 obj-h40083-reading AC-Power-Val obj-h40084-reading AC-Power-Scale obj-h40084-unpack s> obj-h40093-len 2 obj-h40093-reading AC-Energy-Val obj-h40093-unpack l> obj-h40095-reading AC-Energy-Scale obj-h40096-reading DC-Current-Val obj-h40097-reading DC-Current-Scale obj-h40097-unpack s> obj-h40098-reading DC-Voltage-Val obj-h40099-reading DC-Voltage-Scale obj-h40099-unpack s> obj-h40100-reading DC-Power-Val obj-h40101-reading DC-Power-Scale obj-h40101-unpack s> obj-h40103-reading HeatSinkTemp obj-h40103-unpack s> obj-h40107-reading Status room Solar,SolarPV,SolarReport silentReconnect 1 sortUpdate 1 stateFormat {sprintf("%.0f W; %.0f kWh",ReadingsVal("KeSolarEdge","AC-Power",0),ReadingsVal("KeSolarEdge","AC-Energy",0))} userReadings AC-Energy:(AC-Energy-Scale.*) { my $scale = ReadingsVal ("KeSolarEdge","AC-Energy-Scale",0); return (ReadingsVal ("KeSolarEdge","AC-Energy-Val",0) * ( 10 ** $scale) / 1000);;}, AC-Power:(AC-Power-Scale.*) { my $scale = ReadingsVal ("KeSolarEdge","AC-Power-Scale",0); return (ReadingsVal ("KeSolarEdge","AC-Power-Val",0) * ( 10 ** $scale));;}, DC-Power:(DC-Power-Scale.*) { my $scale = ReadingsVal ("KeSolarEdge","DC-Power-Scale",0); return (ReadingsVal ("KeSolarEdge","DC-Power-Val",0) * ( 10 ** $scale));;}, DC-Current:(DC-Current-Scale.*) { my $scale = ReadingsVal ("KeSolarEdge","DC-Current-Scale",0); return (ReadingsVal ("KeSolarEdge","DC-Current-Val",0) * ( 10 ** $scale));;}, DC-Voltage:(DC-Voltage-Scale.*) { my $scale = ReadingsVal ("KeSolarEdge","DC-Voltage-Scale",0); return (ReadingsVal ("KeSolarEdge","DC-Voltage-Val",0) * ( 10 ** $scale));;}, Zustand:(Status.*) { my $Zus = ReadingsVal("KeSolarEdge","Status",0); my $rueck = ReadingsVal("KeSolarEdge","Zustand",0); if (($Zus == 2) and (InternalVal("KeSolarEdge","INTERVAL","") != 600)) { fhem("set KeSolarEdge interval 600"); $rueck = "Nachtmodus"; } elsif (InternalVal("KeSolarEdge","INTERVAL","") != 60) { fhem("set KeSolarEdge interval 60"); $rueck = "Tagmodus"; } return ($rueck);; } webCmdLabel {sprintf("AC-Energy %.3f",ReadingsVal("Solaredge","AC-Energy",0));;}
Dummys anlegen
Zur Verwendung der "at"s werden Dummys benötigt
define pv_energyday_log dummy define dum_pv_energyday_log dummy define dum_pv_energyday_read dummy define dum_pv_energymonth_log dummy define dum_pv_energymonth_read dummy define dum_pv_energytoday dummy define dum_pv_energytomonth dummy define dum_pv_energytoweek dummy define dum_pv_energytoyear dummy define dum_pv_energyweek_log dummy define dum_pv_energyweek_read dummy define dum_pv_energyyear_log dummy define dum_pv_energyyear_read dummy define dum_pvdcpower dummy define dum_pvdcvolt dummy define dum_pvenergy dummy define dum_pvloss dummy define dum_pvpower dummy
at Devices in FHEM
Auslesen der Daten, da das ModbusAttr nicht immer geht:
at_solaredge
+*00:20:00 { if (Value("KeSolarEdge") eq "opened") { my $ACEnergy = fhem ("get KeSolarEdge AC-Energy"); my $ACEnergyScale = fhem ("get KeSolarEdge AC-Energy-Scale"); my $ACE = 0; my $day = Value("dum_pv_energyday_read"); my $week = Value("dum_pv_energyweek_read"); my $month = Value("dum_pv_energymonth_read"); my $year = Value("dum_pv_energyyear_read"); if (($ACEnergy ne "No Data") and ($ACEnergyScale ne "No FD")) { my $ACE = $ACEnergy * (10 ** $ACEnergyScale); if ($ACE > 0) { fhem ("set dum_pvenergy " . $ACE); fhem ("set dum_pv_energytoday " . ($ACE - $day)); fhem ("set dum_pv_energytoweek " . ($ACE - $week)); fhem ("set dum_pv_energytomonth " . ($ACE - $month)); fhem ("set dum_pv_energytoyear " . ($ACE - $year)); } } #Log 1, "at_Solaredge: PV-Energy " . $ACE . "\n"; my $ACPower = fhem ("get KeSolarEdge AC-Power"); my $ACPowerScale = fhem ("get KeSolarEdge AC-Power-Scale"); my $ACP = 0; my $DCP = 0; if (($ACPower ne "No FD") and ($ACPower ne "No Data") and ($ACPowerScale ne "No FD")) { $ACP = $ACPower * (10 ** $ACPowerScale); fhem ("set dum_pvpower " . $ACP); #Log 1, "at_Solaredge: PV-Power " . $ACP . "\n"; my $DCPower = fhem ("get KeSolarEdge DC-Power"); my $DCPowerScale = fhem ("get KeSolarEdge DC-Power-Scale"); if (($DCPower ne "no FD") and ($DCPowerScale ne "no FD")) { $DCP = $DCPower * (10 ** $DCPowerScale); if ($DCP != 0) { fhem ("set dum_pvdcpower " . $DCP); fhem ("set dum_pvloss " . sprintf("%.1f", ($DCP - $ACP))); } } } my $DCVoltage = fhem ("get KeSolarEdge DC-Voltage"); my $DCVoltageScale = fhem ("get KeSolarEdge DC-Voltage-Scale"); my $DCV = 0; if (($DCVoltage ne "no FD") and ($DCVoltage ne "No Data") and ($DCVoltageScale ne "no FD")) { $DCV = $DCVoltage * (10 ** $DCVoltageScale); fhem ("set dum_pvdcvolt " . $DCV); } my $Status = fhem ("get KeSolarEdge Status"); if ($Status ne "no FD") { if ($Status == 2) { fhem ("modify at_solaredge +*00:20:00"); } else { fhem ("modify at_solaredge +*00:01:00"); } } } else { Log 1, Value("KeSolarEdge"); fhem ("modify at_solaredge +*00:01:00"); } }
und eines um die Werte täglich zurück zu setzen
at_midnight
*24:00 { # Abspeichern der täglichen, wöchentlichen und monatlichen Werte use Time::Local; my ($Psec,$Pmin,$Phour,$Pmday,$Pmonth,$Pyear,$Pwday,$Pyday,$Pisdst) = localtime(); if(Value("KeSolarEdge") eq "opened") { my $pvenergy = fhem("get KeSolarEdge AC-Energy"); Log 5, "at_midnight AC-Energy" . " " . $pvenergy; if ($pvenergy ne "No FD") { my $pvet = Value("dum_pv_energyday_read"); #Log 5, "at_midnight dum_pv_energyday_read " . $pvet; fhem ("set dum_pv_energyday_log " . ($pvenergy - $pvet)); #Log 5, "at_midnight dum_pv_energyday" . " " . $pvenergy; fhem ("set dum_pv_energyday_read " . $pvenergy); #Log 5, "at_midnight dum_pv_energyday_read" . " " . $pvenergy; fhem ("modify at_midnight *24:00"); if ($Pwday == 1) { my $pvet = Value("dum_pv_energyweek_read"); fhem ("set dum_pv_energyweek_log " . ($pvenergy - $pvet)); fhem ("set dum_pv_energyweek_read " . $pvenergy); } if ($Pmday == 1) { my $pvet = Value("dum_pv_energymonth_read"); fhem ("set dum_pv_energymonth_log " . ($pvenergy - $pvet)); fhem ("set dum_pv_energymonth_read " . $pvenergy); } if ($Pyday == 1) { my $pvet = Value("dum_pv_energyyear_read"); fhem ("set dum_pv_energyyear_log " . ($pvenergy - $pvet)); fhem ("set dum_pv_energyyear_read " . $pvenergy); } } else { fhem ("modify at_midnight +00:01"); Log 2, "at_midnight Solaredge AC-Energy No FD" } } else { fhem ("modify at_midnight +00:01"); Log 2, "at_midnight Solaredge not opened" } }
Log
Das ModbusDevice legt sich ein eigenes Log an. Um aber übersichtliche Grafiken zu bekommen werden die Daten des Dummy benötigt. Hier hilft ein Logfile
define FileLog_KePv Filelog %L/pv-%Y.log dum_pv*.*
Grafiken
Todo: Beschreibungen zu SVG hinterlegen |
Links
- Solaredge: Installationsanleitung
- Solaredge: Sunspec Protokoll